EN US. Router# show platform hardware capacity system System Resources PFC operating mode: PFC4 Supervisor redundancy mode: administratively sso, operationally sso Switching resources: Module Part number Series CEF mode 6 VS-SUP2T-10G supervisor CEF Router# This example shows how to display VLAN information: Platform scalability: Delivering up to 80 Gbps per slot of switching capacity on E-Series chassis; 2-Terabit aggregate bandwidth capacity using the 6513-E chassis, scaling to 4-Terabit capacity with. Cisco announced some new modules for Cat6500 last month. The last day to order the affected product(s) is April 30, 2016. module 7 asic-8 temperature: 70C. Page 2 of 22 Contents Introduction VS-S2T-10G= Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4-S-65-S720= WS-SUP720-3B w/512MB and 512PCMCIA. Line Number Item Name Description Service Duration Lead Time Included Item Quantity ListPrice Extended ListPrice Discount % Selling Price 1. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. Product Overview. also i have ordered WS-X6848-SFP-2T but in show inventory as WS-X6848-SFP. We are currently using the SUP720-3B and using the 1G SFPs on board. 1 VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 21 days $ 28,000. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. Therefore, you cannot have both 1M IPv4 unicast and 512K IPv6 unicast entries at the same time. The modules also work in Catalyst 6500 Series Switches. 256 Gbps) fabric than the SFM or SFM2, also on the supervisor card, itself. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. Mod Ports Card Type Model Serial No. 2 (50r)SYS2. 1ms of signal updating cycleHigh-density fiber line cards for campus core and distribution. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Mod Ports Card Type Model Serial No. >> i have a Cisco 6504E with a VS-S2T-10G and a small problems with two card: >> >> *Mar 25 17:20:06. Can you let me know if the following kit list will support the 6148 line card in VSS configuration - Cards and Modules 1. 1445. The initial cost will be high but you'll have more room for growth. All forum topics; Previous Topic; Next Topic; 2 Replies 2. The forwarding engine on Supervisor. $88,000. Solved! Go to Solution. Here are the statistics before the ISSU process: The Catalyst 6500 chassis with Switch ID 1 is Active and the Switch with ID 2 is Standby (Hot). Step 3 Ensure that the pre-requisites mentioned in the Before you Begin page are satisfied and then click Begin . I have WAN connection connected on port on Sup card on each chassis and they are in a port-channel. 部分Cisco. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. 2 8 DCEF2T 8 port 10GE WS-X6908-10G SAL190696FB. Chinese; EN US; French; Japanese; Korean; PortugueseThese are based on the Supervisor Engine 2T and the Supervisor Engine 720-10G. The latter in the former is limited to 80 Gbps per line card slot. C6K 8P 10G Ethernet module w/DFC4XL (Trustsec) w/2D Barcode: C6800-8P10G: Catalyst 6800 8 port 10GE with integrated DFC4 – CF-ADAPTER-SP: SP adapter for SUP720 and SUP720-10G: VS-S2T-10G: Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 – MEM-A-MSFC3-1GB: 1GB Memory Upgrade Option: VS-S2T. 10-08-2019 08:17 AM. Platform scalability: Delivering up to 80 Gbps per slot of switching capacity on E-Series chassis; 2-Terabit aggregate bandwidth capacity using the 6513-E chassis, scaling to 4-Terabit capacity with VSS. 0(1)SY7a ) with VS-SUP2T-10G. 1(2)SY16—20 February 2020 • Release 15. Finally, it describes how to attach network interface cables (optical and copper) to the modules. VSS. module 5 asic-2 temperature: 37C. Cisco Catalyst 6500 Series Supervisor Engine 2T Network Module (VS-S2T-10G) 1 product rating. 1. module 1: module 1 power-output-fail: OK module 1 outlet temperature: 66C module 1 inlet temperature: 51C module 1 asic-13 temperature: 79C module 1 asic-14 temperature: 81C module 1 EARL outlet temperature: 47C module 1 EARL inlet. PRODUCT IS NEW AND IN OPEN CONDITION. Thanks for your comment! Hi I'm confused about what is the best procedure to replace a failed SUP2T-10G on VSS because I founded 2 ways: 1° - Replace the failed SUP -Copy the Same IOS on the new SUP -Configure the VSS: switch virtual domain 100 switch 1 priority 200 !Hi experts, I have two 6500 in VSS. 5Ghz per core. Options. You can use this document in order to use the bootable image from the old supervisor and boot the new supervisor. That's because although your OP asked about a 6708, your installed card in a 6908. Page 1 of 1 Start over Page 1 of 1 . End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. No. 652). Soon,i have another same 6807(VS-SUP2T-10G*2,C6800-32P10G*2). bin. 1 CPU Daughterboard VS-F6K-MSFC5 xxx 1. the 6513-VS-SUP2T-10G supervisor engines do support VSS. which. VS-S2T-10G . End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6816 10 GE Line Card and Select Accessories 13-Feb-2017. Logos remain the. Catalyst 6506-E Switch: Access product specifications, documents, downloads, Visio stencils, product images, and community content. Global Price in USD. We have no test 6500 to install the replacement supervisor engine to and put on the correct IOS and config in advance of the replacement. Doc Preview. ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. Catalyst 6500 10 Gigabit Ethernet For Sup2T WS-X6908-10G-2T-RF The Cisco Catalyst 6900 Series 8-port 10 Gigabit Ethernet Fiber Module is the first 10 Gigabit Ethernet module that supports Cisco TrustSec and layer 2 encryption in hardware to enable IEEE 802. Cisco Catalyst 6500 Catalyst 6500 Sup2T VS-S2T-10G-XL-RF VS-S2T-10G-XL-RF The Cisco Catalyst 6500 Supervisor Engine 2T is designed to deliver higher performance,. However this card seems not to be supported by the SUP2T-10G supervisor. 11 slot chassis * 160 Gbps= 1760 i. BTW, Reza mentions the sup and DFC XL feature needs to match, i. 1ae (MACSec) encryption for Role-Based Access Control (RBACL) functionality. Global Leader of Cybersecurity Solutions and Services | FortinetBeginner. I am trying to apply queueing configuration on the interface but failed. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. The documentation set for this product strives to use bias-free language. #sh rom-monitor slot 1 sp Region Gold: version: V12. 393. If you are looking for other parts in addition to the VS-SUP2T-10G VS-F6K-PFC4 , then please contact us by. Up to 25. pdf - F4F1AS6152AC07. 03-27-2012 01:46 AM - edited 03-07-2019 05:48 AM. . 5(1)SY1, page 53 † New. Our flagship switching product line, Cisco Catalyst 6500 provides built-in flexibility and versatility when deployed in the campus, data center, WAN, and Metro Ethernet networks. SPA. The documentation set for this product strives to use bias-free language. 15. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6816 10 GE Line Card and Select Accessories 13-Feb-2017. 206. 11-26-2018 09:12 AM. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. VS-C6509E-S720-10G Catalyst Chassis+Fan. The Cisco Nexus 7000 4-Slot chassis with two I/O module slots supports up to 96 x 1 and 10 Gigabit Ethernet ports, 12 x 40 Gigabit Ethernet ports and 4 x 100 Gigabit Ethernet ports, meeting the needs of small to medium-size data centers, co-locations, access- and aggregation-layer deployments,. 00 66% OFF. (s2t54-ADVIPSERVICESK9-M), Version 15. Supervisor Engine 2T integrates a high-performance 2. The MSFC3 is an integral part of the Supervisor Engine 720, providing high performance, multilayer switching and routing intelligence. 711: %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has. Both switches used Supervisor Engine 2T 10GE , VS-SUP2T-10G 5 ports as follows: C6509-E sho module Mod Ports Card Type Model --- ----- ----- ----- 1 486 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17163A4C 8 40 DCEF2T 8 port 40GE / 32 port 10GE C6800-32P10G SAL2120011E Mod MAC addresses Hw Fw Sw Status. See more detailed modulesThe J9309A four-port SFP+ module only supports 10G transceivers. We have VS-SUP2T-10G for sale, both refurbished and new, at prices typically up to 90% less than the original vendor price. Free shipping. Mod Online Diag Status---- ----- 1 Pass 3 Pass 4 Pass 5 Pass 6 Pass . 393. 0ffd. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. To put it simple, is a card in the line card which provides certain most useful lookup functions. 40-port 25G/10G (SFP28) and 2-port 100G/40G (QSFP28) with C9600-SUP-1. The suggested release is 15. Power denied. $149. A Bridge Connecting IT Hardware to The World Routers Switches Firewalls Wireless Servers Storages Solutions Services About Us ×. Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. 1 Ok. 1(2)SY10 to a newer release. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1817R0YH 6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL1815PZPK. 1ae with no additional latency. VS-SUP2T-10G*2,C6800-32P10G*2. Search for:. Chinese;. They enable security, mobility, application performance, video, and energy savings over an infrastructure that supports resiliency, virtualization, and. Modules:WS-X6908-10G ,WS-X6848-SFP,WS-X6908-10G ,WS-X6848-GE-TX , VS-SUP2T-10G . ! And then I found that VS-SUP2T-10G's Factory ID was VS-S2T-10G! But I don't know the difference between them. 2(50r. The last day to order the affected product(s) is July 31, 2015. . 56. Community. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. Hi, I have two vs-c6509E-SUP2T switches. Cisco Catalyst 6500系列Supervisor Engine 2、交换矩阵模块2 以及部分附件和软件版本终止销售 (EOS)和产品生命期终止 (EOL)声明 26-Aug-2016. LTB Date. 41 x 1. Catalyst 6500/Cisco 7600 Supervisor 720 Fabric MSFC3 PFC3B . Price Trend of VS-S2T-10G. Name VS-S2T-10G VS-S2T-10G-XL IPv4 routing In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** IPv6 routing In hardware Up to 390 Mpps ** In hardware Up to 390 Mpps ** L2 bridging In hardware Up to 720 Mpps ** In hardware Up to 720 Mpps ** MPLS MPLS in hardware to enable use of Layer 3 VPNs and EoMPLS tunneling. module 5 asic-4 temperature:. So, I think, the Q&A is correct. To create to an Instant Access deployment profile, do the following: Step 1 Choose Services > Network Services > Instant Access . 6 Tbps in wired switching capacity, with up to 6. I have 3 pairs of 6807 VSS switches. On the 1st chassis I upgraded we had no problems and so I "borrowed" a known working SUP2T and tried it in that. VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4. 37 435. Tell me more about this line card: Was the line card sourced from a "used" seller? And did the owner disable password-recovery feature?Find many great new & used options and get the best deals for Cisco Catalyst 6500 Series Supervisor Engine VS-SUP2T-10G at the best online prices at eBay! Free shipping for many products!NEW OPEN SFP-10G-SR. module 7 RP outlet temperature: 43C. 40. Make sure to start with the VSS, both the devices has same model and. CISCO VS-S2T-10G, VS-SUP2T-10G,CMUCAB3BAA SUPERVISOR 2T WITH INTEGRATED SWITCH FABRIC/PFC4 AND 2 PORTS 10GBE. The Cisco Catalyst 6807-XL chassis (Figure 1) is built to be capable of delivering up to 11. I have this problem too. 11-17-2016 05:43 AM - edited 03-08-2019 08:11 AM. BOM. C6880-X-LE-SUP. BOM. wrote: Im facing huge packet loss with only longer distances affected. (Sup VS-SUP2T-10G) Reviewed in the United States on 9 September 2012. %C6KENV-4-MINORTEMPALAR. Any advice would be appreciated. 5cd9. 02. This document is Cisco Public Information. So, to reitterate for my own clarification, the X6700-GE-TX with CFC is 100% compatible with the SUP-2T running. SPA. The VS-C6509E-SUP2T Cisco Catalyst Manageable Switch offers advanced security features to protect the network from various security threats. Free PDF of Cisco VS-S2T-10G-XL. Conditions: reload. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. Hello, I have a 6506E chassis that I am upgrading to a pair of SUP2Ts. VS-SUP2T-10G-MSFC5 Supervisor Engine 2T with MSFC5 daughter card. VS-S720-10G: Cat 6500 Supervisor 720 with 2 x 10GbE. 5Ghz per core. Read line card data sheet. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. switch 2 module 5: switch 2 module 5 power-output-fail: OK switch 2 module 5 outlet temperature: 40C switch 2 module 5 inlet temperature: 26C switch 2 module 5 device-1 temperature: 34C switch 2 module 5 device-2 temperature: 36C switch 2 module 5 asic-1 temperature: 64C switch 2 module 5 asic-2. Consider switching to something new: The Cisco Catalyst 9400 Series Switches offer greater speed, performance and security. 3 CPU Daughterboard VS-F6K-MSFC5 xxxxxxxxxxx 3. It is strange I cannot find a public datasheet for sup2T. VS-SUP2T-10G= Sup2T Baseboard spare: There is no replacement product available. Cisco announces the end-of-sale and end-of-life dates for the Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. The Gigabit Ethernet modules serve campus and data center networking requirements in enterprise, commercial, and service provider environments. I have this problem too. Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL Cisco Catalyst 6500 Series Supervisor Engine 2T Power Supply Compatibility * Indicates EoS Power Supply AC: 1400W, 950W* DC: 950W* AC: 2700W DC: 2700W AC: 2500W*, 3000W, 4000W, 6000W, 8700W DC: 2500W, 4000W,. That is correct. VS-S2T-10G-XL Cisco 6500 Supervisor 2T VS-S2T-10G-XL Catalyst 6500 Supervisor 2T 80G System XL WS-F6700-DFC3B Catalyst 6500 Dist. This chapter describes how to safely install, remove, and verify the operation of the Ethernet switching modules in the Catalyst 6800 series switches. I need to enable QoS on these switches, primarily to trust dscp and also to prioritise voice traffic. Les clients ont jusqu'au 30 octobre 2020 pour commander les produits concernés. There's also a VS-SUP2T supervisor card. Mod Sub-Module Model Hw. . Hi everyone, I'm having some difficulty understanding QoS on Sup2T. The new sup2t has been shipped to site, however, the failed sup has already been removed and sent back to Cisco so I dont have the old compact flash card, nor do I have a space chassis to pre-stage the replacement sup. Switch Number: 101 Role: FEX----- ----- Mod Ports Card Type Model Serial No. Each Chassis has two VS-SUP2T-10Gs. 02-06-2013 07:40 AM - edited 03-07-2019 11:33 AM. Product. It has 1G fiber and 1/10G fiber options, as well as several 10/100/1000 and 100/1000/2. VS-SUP2T-10G Catalyst 6500 Supervisor Engine 2T Baseboard VS-F6K-PFC4 Cat 6k 80G Sys Daughter Board Sup2T PFC4 MEM-SUP2T-2GB Catalyst 6500. Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Humidity (RH) ambient (noncondensing) 10 to 90%. Options. View the benefits of upgrading >. The Cisco Nexus 7000 Series Supervisor2 (Sup2) Module (Figure 3) is based on a quad-core Intel Xeon processor with 12 GB of memory and scales the control plane by harnessing the flexibility and power of the quad cores. This card is not oversubscribed. They include a 48-port Gigabit Ethernet Copper Module and 48-port Gigabit Ethernet Fiber Module. It seems like I cannot do ISSU with this upgrade. Can I mix a Cisco Supervisor Engine 2T with Sup720-10G in a VSS-configured system? A. VS-C6509E-SUP2T-RF. The Gigabit Ethernet modules serve campus and data center networking requirements in enterprise, commercial, and service provider environments. 18. B. 8aff 1. 73 inches : Item Dimensions LxWxH 15. WS-SUP720 Supervisor Engine 720 with PFC3A daughter card and integrated MSFC3 and switch fabric. Current version is. module 7 asic-4 temperature: 64C. Cisco 7613. Catalyst 9600 Chassis and Line Cards with C9600X-SUP-2. 0. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL17110FMR 5 4 CEF720 4 port 10-Gigabit Ethernet WS-X6704-10GE SAL12469V08. EOS for Selective Cisco Catalyst 6503,Catalyst 6506 and Catalyst 6509 Chassis 08/Jan/2014. End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500/6500-E Series 1 Gigabit Ethernet Fiber and Copper Line Cards and Accessories 31-Oct-2016. White Paper © 2011 Cisco and/or its affiliates. module 7 device-1 temperature: 40C. 6 Policy Feature Card 4 VS-F6K-PFC4 2. A Bridge Connecting IT Hardware to The World Routers. Catalyst 9600 Chassis and Line Cards with C9600X-SUP-2. Cisco VS-S2T-10G Datasheet Cisco VS-S2T-10G Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4 VS-S2T-10G Cisco VS-S2T-10G Cat 6500 Sup 2T with 2 x. 07-02-2012 08:42 AM. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. we are planning to install C6800-8P10G= Interface Module on our WS-C6509-E (two switches configured on VSS). Except for the 6708-10GE, all 6XNN line cards must have their CFC/DFC upgrade to CFC/DFC4 in order for them to get supported by the Sup2T. VS-S2T-10G VS-S2T-10G XL C6800-SUP6T C6800-SUP6T-XL You can also use these 40-GB modules with the Cisco FourX Converter Module 4: WS-X6904-40G-2T WS-X6904-40G-2TXL Cisco 10GBASE Dense Wavelength-Division Multiplexing SFP+ Modules Data Sheet. I was looking at the data sheet for the VS-S2T-10G and there was no compatibility mentioned with the WS-X6708-10GE module. (VS-S2T-10G) CISCO VS-SUP2T-10G SUPERVISOR ENGINE: United Kingdom: Dighi(Pune) NOS: 2: 802,731: 401,365: Jan 15 2016: 85176910 (VS-S2T-10G) CISCO VS-SUP2T-10G SUPERVISOR ENGINE: United Kingdom: Dighi(Pune) NOS: 1: 398,068: 398,068: Nov 27 2015: 85176910: VS-S2T-10G-XL CISCO CATALYST 6500. Both switches need to run the same IOS version (check with 'sh ver'). 00. Be aware that you have to also acquire a DFC4-A or DFC4-AXL which is a daughtercard of the line card. Compact Flash. Itprice. Product: VS-S2T-10G Product Description: Cat 6500 Sup 2T with 2 x 10GbE and 3 x 1GbE with MSFC5 PFC4. 0(1)SY VS-S2T-10G. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report Inappropriate Content 04-17-2018 08:23 AM - edited 03-08-2019 02:41 PM. Solved: Hi, in our core WS-C6509-E (IOS Software- 15. The entire process is pretty straight forward. I need to copy an image from USB to a SUP2T but the USB port appears to be disabled. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible with Supervisor DFC. Supervisor Compatibility C6800-SUP6T C6800-SUP6T-XL VS-S2T-10G VS-S2T-10G-XL. 00BOM. Again, not very familiar with the sup2T, but on a 720 you can specify just a device as part of the boot string, and the boot process will look for any valid image (I believe restricted to the root of the device) and boot it. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500 Supervisor Engine 720/32. 2+ VSS mode support as shown in the Release Notes. e. you can run a show mod and you will see the serial numbers for the modules are different than the chassis. Labels: Labels: Catalyst 6000; LAN Switching; 0 Helpful Reply. 098a. Using IOS Image: s2t54-adventerprisek9-mz. SFP-10G-SR, used for high-speed data transmission applications, supports 300m by MMF; SFP-10G-LRM supports 220m on standard FDDI grade multimode fiber (MMF) and 300m on standard single-mode fiber (SMF, G. Supervisor Engine 2T integrates a high-performance 2-Terabit crossbar switch fabric that enables 80 Gbps switching capacity per slot on all Cisco Catalyst 6500 E-Series Chassis. Sup2T is totally different from Sup2. 04-16-2017 08:35 AM. Working in conjunction with the Catalyst ® 6500-E/6807-XL Supervisor Engine 2T/2TXL (VS-S2T-10G & VS-S2T-10GXL), they can serve different needs on. 001a to 503d. Cisco announced some new modules for Cat6500 last month. The scope of delivery corresponds to the product. Transceiver: X2-10GB-SR (is compatable with Sup2T have already checked on matrix) Modules are up, no erros, all Green , have. 7 PwrDown. I am not comfortable with this chart as it does not list the software requirement which could imply it is not compatible when used with the SFP-H10GB-CU5M. It supports both switch-to-switch and host-to-switch hardware-based encryption on all uplink ports and all WS-X47XX series line cards. mark that VSS is not in use First question, what is the latest recommended release I can safely upgrade to. The Cisco Catalyst 4500E Supervisor Engine 7L-E builds on the success of its predecessor,. Download the datasheet of Cisco VS-S2T-10G. it is not mentioned in the datasheet just populating the 13 slot chassis switch with 4 port 40Gig module and doing calculation, Maths: 40gig * 4 ports = 160 Gbps. 99. 423. 70. $47,000. Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. The entire process is pretty straight forward. All rights reserved. Either two VS-SUP2T-10G or two VS-SUP2T-10G-XL supervisor engines. 44. 75. Triton Datacom Online is the #1 source for refurbished , used and new VoIP telephony equipment, headsets, IoT equipment, switches and routers from Cisco and Polycom IP. Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C). --- ----- ----- ----- ----- 5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR. Manufactured by Cisco. Verified Purchase. This modular switch stands for virtualization, highest availability, integrated security, best possible support for convergent applications and extensive investment protection. 46W from both 6000W supplies, and if one of the them fails, it will still use 2504. VS-S2T-10G | The Cisco Catalyst 6500 Series is the flagship among switching platforms. VS-10G. Cisco annonce la date d’arrêt de commercialisation et de fin de vie de Cisco Catalyst 6506-E, Catalyst 6509-E, Catalyst 6509-V-E, Catalyst 6513-E, VS-S2T-10G, VS-S2T-10G-XL, Bundles and accessories. Figure 4. bin) If not, is there a follow-on p. Switch Model : Cisco C6905-E. g. Cisco Nexus 7000 Series Supervisor2 Module. Depending on the sizes of the frames making up the incoming traffic, the actual enforced level might differ from the configured. 3 8 DCEF2T 8 port 10GE WS-X6908-10GThe 4-port 10 Gigabit Ethernet fiber module (Figure 4) has no oversubcription and is designed for deployments in which line rate is important. Mark as New; Bookmark;Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. A faster CPU and expanded memory compared to the first-generation. 08-05-2012 07:57 PM. 2 8 DCEF2T 8 port 10GE WS-X6908-10G . Page 2 of 22 Contents IntroductionEOL13211 - Amended. WS-SUP720-3B Supervisor Engine 720 with PFC3B daughter card and. 2GB for Lite and XL (4GB upgrade with 2GB memory upgrade (2+2) NVRAM. About this product. Catalyst Chassis+Fan Tray+Sup720-10G; IP Base ONLY incl. We only have VS-SUP2T-10G and C6800-32P10 in our VSS. SY6. 5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1825UZQ4 Mod MAC addresses Hw Fw Sw Status 5 503d. N/A. My First question is Can i configure VSS with this switches, as some documents say should require (Virtual Switching Supervisor 720-10GE (VS-S720-10GE-3C and VS-S720-10GE-3CXL) Secondly if yes can i use only one 10G link as VSL between two switches. 0f9c. Note these both require the High Speed Fan and a 2500 watt power supply. 39. We started receiving the following errors : from show log : %C6KENV-4-MINORTEMPALARM: EARL 7/0 device-1 temperature crossed threshold #1(=110C). VSS. Hall of Fame Guru Options. Which alternative card should I take for this EOL linecard, or can I use the proposed linecard (use extra daughtercard DFC4)?Symptom: Cat6500 %LICENSE-6-RECOVERED message output when reload device. 5(1)SY OL-20679-01 Chronological List of Releases † New Features in Release 15. below is the show inventory on my switch. module 7 asic-4 temperature: 64C. Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3C Cisco Catalyst 6500 Series Supervisor Engine 720-10G-3CXL Cisco Catalyst 6500 Series Supervisor Engine 2T Power Supply Compatibility * Indicates EoS Power Supply AC: 2500W*, 3000W, 4000W, 6000W, 8700W DC: 2500W, 4000W, 6000W Module Compatibility All modules based on the software release in. Find answers to your questions by entering keywords or phrases in the Search bar above. 00. Regards. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. I've done some digging where it seems to be the cards aren't supported by the VS-SUP2T-10G that is install. EOS/EOL for 64MB Compact Flash for Cisco Catalyst 6500. 0f9c. %DOSFS-5-DIR_ENTRY_CORRUPTION: licdisk:1: has corrupted directory entries, Run fsck to get disk back to stable state If fsck failed to get the device back to stable state, Issue format on the device. ChiefTeam538. In VSS mode, unsupported. Catalyst 9300X 10G, 25G, 40G, mGig and 100G Catalyst 9300 Stackwise-1T (480G when stacking with Catalyst 9300 model) 48x 10G (Larger Power Budget) Up to 100G IPsec* (2x hosting resources over models) Catalyst 9300 10G, 25G, 40G and mGig Stackwise-480 48x5G and 24x10G Catalyst 9300L Stackwise-320 12x10GI am preparing to do an upgrade from Sup720 to Sup2T on a Catalyst 6509E. The link below gets you started:i have a Cisco 6504E with a VS-S2T-10G and a small problems with two card: *Mar 25 17:20:06. Options. Does anyone know how to enable it? comments sorted by Best Top New Controversial Q&A Add a Comment blacksheep5405 • Additional comment actions. VS-S2T-10G-XL Supervisor Engine 2T-10GE with PFC4XL. VSS VS-C6509VE-SUP2T Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY incl VSS Upon LDoS of the Bundle PIDs, customers have the option to book Service Contracts on the individual components of the Bundle, based on components support availability. Catalyst 9600 Series Switches. One VSS pair has more C6800-32P10G that the other. Catalyst Chassis+Fan Tray + Sup2T; IP Services ONLY. VS-C6513E-SUP2T5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR. The cost per port for 10GbE on the 6509 is also higher than other platforms, so if you need a lot of 10GbE and possibly 40/100GbE then you should start looking at the Nexus line. Sup Engine is not able to sync each other and standby Sup restart when the active Sup is detach. Check if the commands needed are available. VS-S2T-10G= Item Weight 12. Specifications. W/VS-F6K-PFC4. Buy Cisco Network Accessory VS-SUP2T-10G. To upgrade from VS-S2T-10G to VS-S2T-10G-XL, remove VS-F6K-PFC4= from the corresponding supervisor engine and install VS-F6K-PFC4XL=. Hello, On the configuration tools I cannot build in 3 x SFP (1G) in to the Sup2T?! But on a Cisco QA document for the Sup2T is states: The 3 x GE SFP and the 2 x 10G uplink ports can be simultaneously used on the Sup 2T. Service Category. 375: %C6KENV-2-DFCMISMATCH: Module 2 DFC incompatible >> with Supervisor DFC. With the 1-Gigabit Ethernet ports disabled, the QoS port architecture of the 10-Gigabit Ethernet ports is 8q4t/1p7q4t. 07. ) Table 2 Supervisor Engine 2T Models; Supervisor Engine 2T Product Numbers Description VS-S2T-10G The VS-S2T-10G is shipped with a factory-installed PFC4 daughter card (VS-F6K-PFC4) and a factory-installed MSFC5 daughter card (VS-F6K-MSFC5). Skip to content. can we install new C6800-8P10G= Interface Module during switch power ON (during working condition), or is it require a downtime. Cisco Catalyst 6500/6800 Supervisor 6T Architecture White Paper. IPv4 unicast takes 1 entry, IPv6 unicast takes 2 entries, IPv4 multicast takes 2 entries, IPv6 multicast takes 4 entries. The Supervisor Engine 2T is designed to deliver hThe Supervisor Engine 2T delivers innovations in scale, security, virtualization, and application monitoring for Cisco Catalyst 6500 Series switches, and reduces TCO. 150-1. 5 5 Supervisor Engine 2T 10GE w/ CTS (Active)VS-SUP2T-10G SAL15056BKR 对于Sup2T,在具有内部代号Eureka的第2层(L2)转发引擎(FE)上执行ELAM 操作 。 请注意,L2 FE数据总线(DBUS)包含L2和L3(L3)查找之前的原始报头信息,而结果总线(RBUS)包含L3和L2查找之后的结果。End-of-Sale and End-of-Life Announcement for the Cisco Catalyst 6500 Switch Accessories 03-Aug-2020. 11-26-2018 09:12 AM. Today I am going to talk about the Quad Sup2T VSS deployment in the environment for Cisco Catalyst 6807-XL switch which is now widely used in the core switching as a replacement of Cisco Catalyst 6500 switches. Mod Online Diag Status---- -----1 Pass 2 Pass 3 Pass. EOS/EOL for 64MB Compact. item 5 NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY NEW SEALED CISCO VS-S2T-10G-XL - Sup2T, 2x10GbE, 3x1GbE - LIFETIME WARRANTY. 3 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G xxxxxxxxxxx . Find software and support documentation to design, install and upgrade, configure, and. The Future Is 40 Gigabit Ethernet White Paper (PDF - 2 MB) Virtual Private LAN Service on Cisco Catalyst 6500 Supervisor Engine 2T. The Cisco Nexus 7700 Supervisor 2E Module is based on a two-quad-core Intel Xeon processor with 32 GB of memory that scales the control plane by harnessing the flexibility and power of the two quad cores, offering high control-plane performance and scalability: for example, support for more virtual device contexts (VDCs) and fabric.